中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Fire resisting Cable  
Fire Retardant Power & Control Cables
Fire Retardant Instrumention Cables
Fire Retardant RS485 Databus Cables
Fire Retardant Data Cables
Fire Retardant Coaxial Cables
Fire Retardant Fiber Optic Cables

PE Insulated, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multipair)

RE-2Y(St)HSWAH 

APPLICATION 

The armoured LSZH sheathed (Part 1 Type 2) cables are generally used when the risk of mechanical damage is 

increased. The galvanized steel wire armour provides excellent protection. Generally, the cables are used within 

industrial process manufacturing plants for communication, data and voice transmission signals and services. Also

 used for the  interconnection of electrical equipment and instruments, the LSZH sheath can reduce toxic smoke 

and fume emission. 

STANDARDS

Basic design to BS 5308 Part 1 Type 2

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); 

CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation   (Vertically-mounted bundled wires & cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; 

CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; 

CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; 

CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

VOLTAGE RATING

300/500V 

CABLE CONSTRUCTION

Conductor: Annealed or tinned copper, sizes: 0.5mm² and 0.75mm² mulitistranded(Class 5), 0.5 mm², 1.0 mm² solid(Class 1), 1.5mm² or 2.5mm², multistranded(Class 2) to BS6360

Insulation: PE.

Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm

Binder tape: PETP transparent tape

Overall Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm²

Inner Sheath: LSZH(Low Smoke Zero Halogen) sheath

Amouring: Galvanized steel wire armour

Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound 

type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti 

rodent and anti termite properties can be offered as option.

COLOUR CODE

Insulation Colour: See Technical Information

Outer Sheath: Black Or Blue

Physical AND THERMAL PROPERTIES

Temperature Range During Operation (Fixed State): -30°C – +90°C
Temperature Range During Installation (Mobile State): -20°C – +50°C
Minimum Bending Radius:  6 X Overall Diameter

Electrical PROPERTIES

Conductor Area Size

 mm2 

0.5

0.5 

0.75 

1.0 

1.5 

Conductor Stranding

 No. x mm 

1 x 0.8 

16 x 0.2 

24 x 0.2 

1 x 1.13 

7 x 0.53 

Conductor resistance max

 ohm/km 

36.8

39.7 

26.5 

18.2 

12.3 

Insulation resistance min

 Gohm/km 

5

5

5

5 

5 

Capacitance Unbalance @ 1 kHz(pair to pair screen) 

pF/250m

250

Max. Mutual Capacitance @ 1 Khz for non Os or Os Cables (Except 1 Pair and 2 Pairs)  

pF/m  

75 

75  

75  

75  

85

Max. Mutual Capacitance @ 1 Khz for Is/Os Cables (Include 1 Pair and 2 Pairs)  

pF/m  

115 

115  

115 

115 

115  

Max. L/R Ratio for adjacent cores(Inductance/Resistance) 

μH/ohm 

25

25 

25 

25 

40 

Test voltage

Core to core

V

1000

1000

1000

1000

1000

Core to screen

V

1000

1000

1000

1000

1000

Rated voltage max

V

300/500

300/500

300/500

300/500

300/500

CONSTRUCTION PARAMETERS

No. of Pairs 

No./Nominal

Diameter of

Strands 

Nominal Conductor 

Cross-

Section Area 

Nominal 

Insulation 

Thickness 

Nominal 

Sheath

Thickness 

Nominal 

Overall

Diameter 

Nominal 

Armour

Thickness  

Nominal 

Sheath

Thickness  

Nominal 

Overall

Diameter 

Approx. Weight 

no./mm 

mm2 

mm 

mm 

mm 

kg/km 

mm 

mm

kg/km 

1

1/0.80

0.5

0.5

0.8

5.5

0.9

1.3

9.9

200

2

1/0.80

0.5

0.5

0.8

6.8

0.9

1.3

11.2

260

5

1/0.80

0.5

0.5

1.1

10.9

0.9

1.4

15.5

460

10

1/0.80

0.5

0.5

1.2

14.4

1.25

1.6

20.1

790

15

1/0.80

0.5

0.5

1.2

16.5

1.25

1.6

22.2

1100

20

1/0.80

0.5

0.5

1.3

18.8

1.6

1.7

25.4

1280

30

1/0.80

0.5

0.5

1.3

22.3

1.6

1.8

29.1

1520

50

1/0.80

0.5

0.5

1.5

28.5

1.6

2

35.7

2100

1

16/0.2

0.5

0.6

0.8

6.2

0.9

1.3

10.6

250

2

16/0.2

0.5

0.6

0.8

7.6

0.9

1.3

12

300

5

16/0.2

0.5

0.6

1.1

12.4

0.9

1.5

17.2

560

10

16/0.2

0.5

0.6

1.2

16.5

1.25

1.6

22.2

970

15

16/0.2

0.5

0.6

1.3

19.2

1.6

1.7

25.8

1240

20

16/0.2

0.5

0.6

1.3

21.7

1.6

1.8

28.5

1640

30

16/0.2

0.5

0.6

1.5

26.4

1.6

1.9

33.4

1770

50

16/0.2

0.5

0.6

1.7

33.4

2

2.1

41.6

2770

1

24/0.2

0.75

0.6

0.8

6.7

0.9

1.4

10.9

280

2

24/0.2

0.75

0.6

0.9

8.4

0.9

1.4

12.8

330

5

24/0.2

0.75

0.6

1.2

13.8

1.25

1.6

19.3

750

10

24/0.2

0.75

0.6

1.3

18.4

1.6

1.8

24.3

1260

15

24/0.2

0.75

0.6

1.3

21.1

1.6

1.9

27

1480

20

24/0.2

0.75

0.6

1.5

24.4

1.6

2

31.4

1890

30

24/0.2

0.75

0.6

1.7

29.5

2

2.1

37

2440

50

24/0.2

0.75

0.6

2

37.6

2.5

2.4

47.3

3210

1

1/1.13

1

0.6

0.8

6.6

0.9

1.3

11

290

2

1/1.13

1

0.6

0.8

8

0.9

1.4

12.6

345

5

1/1.13

1

0.6

1.2

13.5

1.25

1.5

19

790

10

1/1.13

1

0.6

1.2

17.7

1.25

1.7

23.6

1310

15

1/1.13

1

0.6

1.3

20.6

1.6

1.8

27.4

1740

20

1/1.13

1

0.6

1.5

23.8

1.6

1.8

30.6

2040

30

1/1.13

1

0.6

1.5

28.4

1.6

2

35.6

2180

50

1/1.13

1

0.6

2

36.6

2

2.2

45

3500

1

7/0.53

1.5

0.6

0.8

7.5

0.9

1.4

11.9

320

2

7/0.53

1.5

0.6

0.9

9.3

0.9

1.5

14.1

420

5

7/0.53

1.5

0.6

1.2

15.6

1.25

1.6

21.6

940

10

7/0.53

1.5

0.6

1.3

20.9

1.6

1.8

27.4

1500

15

7/0.53

1.5

0.6

1.5

24.6

1.6

1.9

31.2

1970

20

7/0.53

1.5

0.6

1.5

27.8

1.6

2

35.8

2400

30

7/0.53

1.5

0.6

1.7

33.7

2

2.2

42.3

3170

50

7/0.53

1.5

0.6

2

43

2.5

2.5

53.2

5020

 

 

E-mail: uk@addison-cables.com

 